Network Enabler Administrator

Find the documentation you need

1. Install the Network Enabler Administration software. Next you can run the Start\Programs\Network Enabler Administration\ Network Enabler Administrator.

2. Next, you need to find the unit you can either use the Configuration\broadcast search if the PC and unit are on the same subnet or you can use the Configuration\Specify by IP address if you know the IP address of the unit.

3. You can also configure the unit using the web interface (type the IP address in your web browser) but you will still need to use the software to install the virtual serial port.

NOTE: Test assumes the ELBNK to ELITE PI connections are complete.

1. To test the output channel links, set S1, DIP switch 1 to ON.

2. Use the table below to set the S5 DIP switches for the channel to test.
a. If the two-digit display shows Cn and then flashes between D1 and OK, go to Step 4.
b. If the two-digit display shows Cn and then flashes between D1 and –, go to Step 3.

3. Unplug the connector from the output channel jack (JPn) and swap RX+ with TX+, swap RX- with TX-, and then plug the connector back into JPn.
a. If the two-digit display shows Cn and then flashes between D1 and OK, go to Step 4.
b. If the two-digit display still shows Cn and then flashes between D1 and –, contact C.E. Electronics Tech Support department at 419-636-6705, extn. 730.

4. Return to Step 2 for any remaining outputs in use.

5. After testing all of the outputs in use, set S1, DIP switch 1 to OFF.