2107 Industrial Drive
Bryan, Ohio 43506
t: 419.636.6705
f: 419.636.2516
This email address is being protected from spambots. You need JavaScript enabled to view it.

EASI-XXXX | ELEVATOR ALERT STATUS INDICATOR


MINI PI INDICATOR

Ver. 1 Rel. 11.09.18

EASI-XXXX 

EASI-XXXX | 2.8" MINI PI | ELEVATOR ALERT STATUS INDICATOR

The EASI CE Mini PI was designed to increase flexibility and reduce space for the ever changing codes.
 
This Display in it dormant Position allows the User to put a Custom graphic on the screen to reflect and address or logo. Once activated by Conditions of the Elevator, it can Display Fire Messages required by code. It also has the ability to display, Emergency Power, Phone Line    Interruption, Car lighting faults and a Pit Sensor message.

When the Unit is Active in the Fire Phase 1 mode it can even show which cars go into Phase 2 mode by car number at the bottom of the screen. This Multi car mode also is used to show which cars are in the other modes available to this display. When Multiple conditions are active there is the number of messages shown in a small numerical block on the upper left of the screen. Messages are shown by priority, So Fire Phase 1 never leaves the screen until the condition goes away. The code also requires an Audible feature that sounds at the display for the Phone line interruption and the Car Lighting faults. This feature has a resettable button that once depressed it will discontinue the alarm for 24 hours, but the indicator stays active until the fault is corrected and the alarm will resume again in 24 hours if the fault is not   corrected. The disable button feature is accessible by a small hole beneath the display in the metal panel.

The inputs and Outputs to the EASI display are provided in the machine room with Optically insolated inputs and relay outputs.

The EASI Display also has a pit sensor that is triggered by a sensor in the Pit or Pits specific to the bank, with indications to which Pit sensor triggered the fault. The sensors are wired directly into the display at the lobby, then a Relay Output is given in the machine room for the appropriate action to be taken.

 


Typical Applications:

> Fire Phase I & II

> Emgergency Power

> Car Lighting Faults

> Phone Line Interruption

> Pit Sensor Faults

 


Features:

> Color LCD Display

> Resettable Audible Alarm

> USB Updateable

> Backlight dimming feature

 


Option #3:

> S - Phone Sensor

> X - No Phone Sensor

 


Option #4:

> P - Pit Sensor

> X - No Pit Sensor

 


VIEW: CATALOG PAGE    |    PANEL PREP    |   WIRING DIAGRAM    |    E-FLYER